Robust, precise digital indicator
The robust stainless steel case and the battery power enable a flexible operation in various applications and industries. For a precise and quick on-site reading of a pressure value, a digital indicator is the ideal solution. The bar graph display and drag pointer function integrated into the display, as well as retrievable Min/Max peak values, enable effective analysis of the measuring point.
Customised installation
Through its rotatable case, the model DG-10-E can be easily adapted to local conditions. The backlighting also provides easy readability of the display in poor lighting conditions.
Additional programming functions are: Automatic power-off, tare function and password protection. There is unit switching between the units bar, psi and MPa already integrated into the standard model DG-10-S.
Proven sensor technology
For decades, sensors manufactured by Double-An have guaranteed high accuray, long-term stability and repeatability in industrial pressure measurement.
Gauge pressure
bar | Measuring range | 0 ... 5 | 0 ... 10 | 0 ... 20 | 0 ... 50 | 0 ... 100 | 0 ... 160 | 0 ... 250 | 0 ... 400 | 0 ... 600 |
Overpressure limit | 10 | 20 | 40 | 100 | 200 | 320 | 500 | 800 | 1,200 |
Burst pressure | 12 | 25 | 50 | 120 | 800 | 1,000 | 1,200 | 1,700 | 2,400 |
psi | Measuring range | 0 ... 145 | 0 ... 300 | 0 ... 600 | 0 ... 1,450 | 0 ... 2,000 | 0 ... 3,000 | 0 ... 5,000 | 0 ... 7,500 | 0 ... 10,000 1) |
Overpressure limit | 290 | 580 | 1,450 | 2,900 | 4,640 | 7,250 | 11,600 | 17,400 | 21,750 |
Burst pressure | 360 | 725 | 1,740 | 11,600 | 14,500 | 17,400 | 24,650 | 34,800 | 43,500 |
1)DG-10-5 can only display up to 9999 psi
Vacuum and +/- measuring ranges
bar | Measuring range | -1 ... +5 | -1 ... +10 | psi | Measuring range | -30 inHg ... +72 psi | -30 inHg ... +145 psi |
Overpressure limit | 10 | 20 | Overpressure limit | 145 | 290 |
Burst pressure | 12 | 25 | Burst pressure | 170 | 360 |
Digital indicator
| Model DG-10-S | Model DG-10-E |
Type of indication | 7-segment LCD | 7-segment LCD、14-segment LCD (option) |
Digits | 4-digit | 4-digit |
Character size | 11 mm | 11mm and 7mm |
Indication range | -1999 ... 9999 | -1999 ... 19999 |
Update | 200 ms | 200 ms |
Backlighting | no | yes (see "Hardware functions") |
Bar graph with drag pointer function | yes | yes |
Rotatability | no | 300° (see "Hardware functions") |
- Model DG-10-S
- Model DG-10-E
Ordering information: Model / Measuring range / Process connection
Software functions
Function | Model DG-10-S | Model DG-10-E |
Min/Max memory | yes | yes |
Automatic power-off | no | 15, 30, 60, 120 minutes |
Tare function | no | yes |
Unit switching | bar, psi, MPa | bar, psi, MPa |
Password protection | no | yes |
Reset to factory settings | no | yes |
Hardware functions
- Rotatability of the display
The display of the model DG-10-E can be rotated through 300°, thus it can be read from almost any position. Therefore the model DG-10-E can also be used in situations where mounting is difficult. - Backlighting
The model DG-10-E features backlighting so that the display can be easily read, even under poor lighting conditions.
Accessories
- Rubber protection cap (black)
- Minimess connector: Mazimum pressure strength 630 bar
- Sealing for process connection
Voltage supply
The voltage supply is provided via two 1.5 V AA cells.
The operating time is approx. 4,000 hours, when using batteries with a capacity of 2,000 mAh.
Reference conditions
Temperature: 0 ... 60 ℃(32 ... 140°F)
Atmospheric pressure: 860 ... 1,060 mbar (12.5 ... 15.4 psi)
Humidity: <90 % r.h.(non-condensing)
Nominal position: Calibrated in vertical mounting position with process connection facing downwards.
Power supply: 2x1.5V AA cell
Accuracy
Accuracy at reference conditions: ≤ ±0.5% of span ±1 digit1)
1)Restriction for vacuum and +/- measuring ranges in the range of -1 ... 0 bar ≤ ±1.0% of span ±1 digit
Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2).
Calibration accuracy of zero signal: ≤ ±0.1% of span (power-up reset)
Adjustability of zero point: ≤ ±20% of span (via tare function with model DG-10-E)
Temperature error at 0 ... 60℃
Mean temperature coefficient of zero point ≤ ±0.15% of span/10K
Mean temperature coefficient of span ≤ ±0.15% of span/10K
Long-term stability: ≤ ±0.2% of span/year
Operating conditions
Ingress protection (per IEC 60529): IP65
Temperatures
Medium:-30 ... +100℃ (-22 ... 212°F)
Ambient:-10 ... +60℃ (14 ... 140°F)
Storage:-20 ... +70℃ (-4 ... 158°F)
Materials
Wetted parts
Process connection: Stainless steel 316Ti
Sealing material: See "Process connections"
Sensor element: PH grade steel
Non-wetted parts
Case:Stainless steel 304
Front foil and membrane:Polyester